    VRLA Battery Usage Guidelines Valve Regulated Lead Acid Batteries, commonly known as VRLA. In order to ensure the safe operation of our VRLA batteries, correct and accurate procedures must be employed. All individuals who work with VRLA must be made aware of the Dangers, Warnings, Attentions and Suggestions, for proper use of our batteries in order to avoid accidents and injuries. Please read this document thoroughly and retain it for reference in case it is needed in an emergency situation. Our VRLA batteries contain high density energy. Incorrect operation can cause explosion, leaking acid, as well as extreme heat. Those situations can cause harm to an individual who has not read and understood this document. VRLA BATTERY DANGERS: Means extreme danger, will cause a serious injury, even death under improper usage. (1) Do not seal the battery inside of any machinery. Please make sure that the battery is well ventilated. Placing the battery in an hermetically sealed space can cause the battery to explode causing damage to the machinery or extreme personal injury. (2) Do not place the battery in a hermetically sealed space that is closed or close to any source of heat or flame. This could cause the battery to ignite or even explode. (3) All connection cables should be well insulated and not able to short electrically. If the cables do cause an electrical short, that may cause smoke or the battery to cause a large destructive fire. (4) Do not use any metal such as steel wire brush to connect or clean the terminals. Be careful not to drop any personal jewelry, hair pins or any other metallic objects when servicing the batteries. Metal objects can cause an electrical short which can be a source of leaking, heat or a destructive fire. VRLA BATTERY WARNINGS: Means urgent danger, causing the possibility of death or serious injury is less likely; can possibly cause light injury or facility damage under faulty operation. (1) Always use the proper charger and the charging regulations set by CSB Battery. Not following our guidelines and procedures, or using non-approved charging procedures, can cause the battery to leak acid, heat up, or cause a destructive fire. (2) When our batteries are used for medical applications, please be aware of the possibility that the battery could fail. Back-up units should be in place to prevent injuries. (3) The container cannot come in contact with metal products. Please use insulated material that has acid and heat resisting characteristics to be the battery container. Not using insulated materials may cause fire or an explosion by leaking. (4) Do not install batteries close to any location where a spark may occur such as a switch or a fuse. Sparks may cause fire or an explosion. (5) Always wear insulated gloves during any battery servicing activities, otherwise you could get an electrical shock. (6) Do not install a battery in a high traffic area without adequately protecting the battery. Not doing so could cause an electrical shock or fire in case the battery is disturbed or dislodged. (7) Do not burn the battery or throw it into a fire. Doing so may cause the battery to explode and toxic gas to be released. (8) Do not disassemble, reassemble or destroy the battery. Doing so could cause the acid inside the battery to leak and cause severe burns or other accidents. (9) Do not use any dry fabric or other materials to clean the battery that could cause static electricity. Always use a damp cloth that has had the moisture wrung out of it. (10) The battery should be replaced before the expiration date. Upon installation a log of expiration dates should be kept in a handbook or on front of the machinery.  When the battery's performance has only 50% left at 25°C, the battery should be replaced. The battery's life will curtail one half with a raise of each 10°C in temperature. If the discharging current is higher than 0.25CA, the battery's life will be shorted.  When the battery approaches the end of its life, its performance will decrease very fast. The internal exhausted electrolyte and the corrosion of the positive plate may cause a failure. If the battery continues in operation under these conditions, there could be extreme heat, leaking of even explosion. (11) There is sulfuric acid inside of the battery. Please use water if skin or clothes become contaminated by the acid. If acid gets into your eyes, use ample clean fresh water to flush your eyes and seek immediate medical attention. ATTENTION: Means ordinary danger, the chance for serious injury is less. However, light injury or facility damage could be possible with faulty operation. (1) The standard operating temperature for our batteries is 5-35°C (41-95°F). Usage outside this range will cause damage to the battery. (2) Our batteries cannot be used beside any heat source such as a transformer. (3) Do not let water or sea water wet or soak our batteries. (4) Do not leave one of our batteries inside an automobile or any other place with strong sunlight. (5) Do not place our batteries in areas where there is a lot of powder residue. The powder could cause a short in the battery. (6) When using our batteries in a series, connections should be made between the batteries before charging or placing the series under a load. Remember, the positive terminal of the battery must connect to the positive side of the charger or the load. The negative terminal of the battery must connect to the negative side of the charge or load. Otherwise an explosion may occur causing personnel or equipment damage. (7) Be careful when handling batteries or taking them out of their racks or storage units. Please wear protective footwear when handling our batteries.

    u=1184502939,2379780009&fm=23&gp=0.jpg

    CSB电池的产品特点和国际认证

    CSB蓄电池产品特点:1) 防漏液,免维护独特结构设计实现完全密封,配合高效率氧气重组技术,完成水分再生,从而达到不需要加水及免维护之效果。2)高效能,持久耐用电池放电率十分低,室温下(25℃)每月放电低于3%。内阻极低,具有优越的高率放电性能,提供强劲电力。正常浮充状态下,电池寿命可达12年以上(2V系列),或 6-8年(6V/12V系列)。3)安全可靠,符合国际标准UNION友联电池内置安全阀及阻液片,可调节电池内部压力及阻止腐蚀性气体析出,使用安全可靠,通过并获得美国UL安全认证(NO.MH16572
    德国TUV机构IS09002认证(NO.041008759
    中国进出口商检CQC ISO9002证书(NO.4400/981519
    中国信息产业部电信设备进网证书(NO.26-0820-009397
    中国出口商品许可证书(出口免检)
    电力部电力设备检测认可报告
    中国广电总局入网设备认可证书

    中国电信总局设备选型首批入闱厂家

    适合CSB蓄电池的充电器特点

    具有操纵轻便,充电速率快,充电还原服从高,凌驾充电无过充伤害,电压/电流数据表现、具有过压、欠压、过流、输出短路、防反接掩护和过热掩护等功效。可设定恒流充电、恒压充电、浮充或并联操纵功效。充电完成条件:可通过充电定电压时间、充电时间、充电容量的设定,完成充电步伐,并可限定输入范畴,防备过分放电.

    ■ 卓越可靠的产品    公司生产的BABY系列蓄电池以其卓越的大电流放电性能,优良的充电接收能力,先进的极柱密封技术,使蓄电池更能满足后备电源设备、太阳能储能设备、应急电源系统 、电动车的使用要求,且接受OEM订单和特殊型号的研发与生产。 

    ■ 差异化理念与优质服务    公司遵循以市场为导向、以客户为中心、以诚信为原则,苦练内功,保证质量求降本,提高管理求效益,以价廉物美的产品让利于客户。公司将全心全意为用户提供优质的产品和满意的服务,做到“人有我有、人无我有”的产品差异化理念,使我们在共赢的道路上造福于社会和企业。  